  ? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 1/26 no reproduction and redistribution allowed product description: 20 wxga color tft-lcd module auo model name: t200xw02 v0 customer part no/project name : customer signature au o 2006/03/13 approved by: pl chen reviewed by: hong jye hong prepared by: jerry lee please return one copy with your signature and comments for our confirmation. au optronics corporation tel: +886-3-563-2899 fax: +886-3-563-1590 * no reproduction and redistribution allowed pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 2/26 no reproduction and redistribution allowed product specifications 20 wxga color tft-lcd module model name: t200xw02 ( ) preliminary specifications (*) final specifications pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 3/26 no reproduction and redistribution allowed contents interface connections 3-2 color input data refernece 3-5 precautions 8 packing (green mark description) 7 emc 6-2 cover contents record of revisions general description 1 absolute maximum ratings 2 electrical specifications 3 electrical charactreistics 3-1 signal timing specifications 3-3 signal timing waveforms 3-4 power sequence 3-6 optical sfecifications 4 mechanical characteristics 5 6 international standards safety 6-1 item no pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 4/26 no reproduction and redistribution allowed record of revision version date no old description new description remark 0.1 2005/11/14 1 first draft 0.2 2005/12/06 1 lack of electronic spec update electronic spec 2 update 2d drawing 0.3 2006/01/26 3-1 electrical characteristics add the data of electronic items. 3-2 interface connections update the new format and mor e detail information. 3-2 backlight electrical specification add the data of electronic items. 0.4 2006/02/20 1 contrast ratio: 600:1(typ.) contrast ratio: 700:1(typ.) 1 power consumption = 40.7w power consumption = 44.4w 3-1 inrush current= 2a typ. inrush current= 2a max. 3-1 only consider the power consumption of blu only. update the power consumption and include the loss of inverter. 3-2 backlight electrical specification update the ignition voltage under ta= 25 and 0 . update vcfl and pcfl 3-3 signal timing specification update timing table 3-6 power sequence update 4 optical specification update and add color information. 4 viewing angle add the meter as eldim ez contrast 160d. 5 mechanical characteristics update the max of depth value as 24mm. 5 2d drawing rear view lamp cable change form 90mm to 130mm typ. 0.5 2006/03/06 3-2 backlight connector pin configuration to add the description of lamp s cable color 0.6 2006/03/07 3-2 backlight electrical specification (lamp spec) ccfl frequency: min:40 typ.:55 max:70 (khz) 0.7 2006/03/13 1 viewing angle (l/r/u/d) 80/80/80/60 80/80/70/70 3-1 electrical characteristics to add the max. value of power consumption 3-2 backlight electrical specification (lamp spec) ccfl current (icfl): min: 5.0 (ma) ccfl voltage (vcfl): 823~894 (volt) 3-3 signal timing specification combine vertical frequency range a and b. 3-6 power sequence t1 s max value change from 1 to 20 ms 4 optical specification response time: to add the value and the note 4. 4 optical specification viewing angle: 80/80 /70/70 pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 5/26 no reproduction and redistribution allowed 1. general description this specification applies to the 20.0 inch color tft-lcd module t200xw02. this module supports the wxga (1366(h) x 768(v)) screen format and 16.2m colors (6-bits + frc). all input signals are 1 channel lvds interface compatible. this module is without any inverter card for backlight. features -wxga 1366(h) x 768(v) resolution -fast response time (8ms) -50,000 hours lamp life -6 ccfl side light design (cold cathode fluorescent lamp) -high brightness, high contrast ratio -wide viewing angle -low power consumption -green design (rohs compliance) -hdtv ready module application personal tv multi-function media video game console pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 6/26 no reproduction and redistribution allowed * general information the following items are characteristics summary on the table 25 condition: items specification unit note active screen size 20.04 inches 50.9cm diagonal display area 443.61(h) x 249.41(v) mm outline dimension 472.0(h) 276.5(v) 23.0(d) (typ.)* mm without inverter resolution 1366(r,g,b 3) x 768 pixels pixel pitch 0.32475 x 0.32475 pixel arrangement rgb vertical stripe display mode tn mode, normally white display colors 16.2m (6-bit + frc for r,g,b) colors typical white luminance 450 nit (typ.) @ 6.5ma [cd/m 2 ] contrast ratio 700:1(typ.) color gamut 72%(typ.) of ntsc response time 8ms(typ.) (tr+tf) ms viewing angle (l/r/u/d) 80/80/70/70 cr>10 power consumption 44.4 w (typ.)(vdd line +ccfl line)** w @6.5ma electronic interface 1ch lvds frame rate 60hz(typ.), 75hz(max.) hz weight(g) 3000(max) g surface treatment hard-coating 3h, ag rohs rohs compliance * the depth of module is 23mm typ. and 24mm max. ** to consider the loss of inverter s efficiency. pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 7/26 no reproduction and redistribution allowed 2. absolute maximum ratings the following are maximum values which, if exceeded, may cause faulty operation or damage to the unit. item symbol min max unit note logic/lcd drive voltage vdd -0.3 6 [volt] 1 input voltage of signal vin -0.3 3.6 [volt] 1 operating temperature t op 0 +50 [ o c] 2 operating humidity h op 10 90 [%rh] 2 storage temperature t st -20 +60 [ o c] 2 storage humidity h st 10 90 [%rh] 2 note 1 : duration = 50msec note 2 : maximum wet-bulb should be 39 and no condensation. pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 8/26 no reproduction and redistribution allowed 3. electrical specification the t200xw02 requires two power inputs. one is employed to power the lcd electronics and to drive the tft array and liquid crystal. an inverter typically generates the second input, which powers the ccfl. 3-1 electrical characteristics values parameter symbol min typ max unit notes lcd: power supply input voltage vdd 4.5 5.0 5.5 vdc power supply input current idd - 0.72 0.9 a 1 power consumption pc - 3.6 4.5 watt 1 inrush current i rush - - 2.0 a 1 backlight power consumption - 40.8 43.2 watt 2 total power consumption - 44.4 46.8 watt 2 life time 50000 - - hours 3 the performance of the lamp in lcm, for example lifetime or brightness, is extremely influenced by the characteristics of the dc-ac inverter. so all the parameters of an inverter should be carefully designed so as not to produce too much leakage current from high-voltage output of the inverter. when you design or order the inverter, please make sure unwanted lighting caused by the mismatch of the lamp and the inverter (no lighting, flicker, etc) never occurs. when you confirm it, the lcd assembly should be operated in the same condition as installed in your instrument. do not attach a conducting tape to lamp connecting wire. if the lamp wire attach to conducting tape, tft-lcd module have a low luminance and the inverter has abnormal action because leakage current occurs between lamp wire and conducting tape. the relative humidity must not exceed 80% non-condensing at temperatures of 40 or less. at temperatures greater than 40 , the wet bulb temperature must not exceed 39 . when operate at low temperatures, the brightness of ccfl will drop and the lifetime of ccfl will be reduced. note : 1. vdd=5.0v, fv=62hz, f clk = 88mhz , 25 , vdd duration time= 470 s m the power supply input check pattern definition and dissipation reference as below : dot pattern 0.9a (max.) pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 9/26 no reproduction and redistribution allowed 1366*768*3 pixel pixel gray level 255 pixel gray level 0 dot pattern (dot) rgbrgbrgbrgbrgbrgb white pattern 0.69 a 1366*768*3 pixel pixel gray level 255 gray level 255 (white screen) rgbrgbrgbrgbrgbrgb black pattern 0.75 a 1366*768*3 pixel pixel gray level 0 gray level 0 (black screen) rgbrgbrgbrgbrgbrgb vertical gray scale pattern 0.72 a(typ.) 1366*768*3 pixel vertical gray scale r/g/b level 0~level 255 vertical grey scale pattern 2. the lamp power consumption shown above does include loss of external inverter at 25 . the used lamp current is the lamp current typical value. assumption : the efficiency of inverter is 80%. blu actual power is 32.64w, blu power consumption need to consider the efficiency of inverter, and should be 32.64 / 80% = 40.8w (typ) and 43.2w (max). ttl power = 40.8 + 3.6 = 44.4 w . (typ) and 46.8w (max). 3. the life is determined as the time at which luminance of the lamp is 50% compared to that of initial value at the typical lamp current on condition of continuous operating at 25 2 . the lamp current should fix at 6.5ma(typ.) and then keep the 50000hr(typ.) lamp life pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 10/26 no reproduction and redistribution allowed 3-2 interface connections - lcd connector (cn1): jae fi-x30ssl-hf or equivalent - lvds transmitter: sn75lvds83 (texas instruments) or equivalent note: 1. all gnd (ground) pins should be connected together and should also be connected to the lcd s metal frame. all vcc (power input) pins should be connected together. pin no symbol description note 1 reserved open or high auo internal test pin 2 reserved open or high auo internal test pin 3 reserved open or high auo internal test pin 4 gnd ground 5 rin0- lvds channel 0 [polarity: negative] 6 rin0+ lvds channel 0 [polarity: positive] 7 gnd ground 8 rin1- lvds channel 1 [polarity: negative] 9 rin1+ lvds channel 1 [polarity: positive] 10 gnd ground 11 rin2- lvds channel 2 [polarity: negative] 12 rin2+ lvds channel 2 [polarity: positive] 13 gnd ground 14 rinclk- lvds clock [polarity: negative] 15 rinclk+ lvds clock [polarity: positive] 16 gnd ground 17 rin3- lvds channel 3 [polarity: negative] 18 rin3+ lvds channel 3 [polarity: positive] 19 gnd ground 20 reserved open auo internal test pin 21 lvds option* low for jeida, high/open for ns 22 reserved open 23 gnd ground 24 gnd ground 25 gnd ground 26 vdd (+5v) 5v, dc, regulated 27 vdd (+5v) 5v, dc, regulated 28 vdd (+5v) 5v, dc, regulated 29 vdd (+5v) 5v, dc, regulated 30 vdd (+5v) 5v, dc, regulated lvds option : h (3.3v) or open ns (default) l (gnd) jeida pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 11/26 no reproduction and redistribution allowed u lvds option = l (gnd) b4 na de de b4 b5 b6 b7 na b5 r2 r7 g2 g2 r2 r3 r4 r5 r6 r3 g3 b2 b3 b3 g3 g4 g5 g6 g4 previous cycle current cycle next cycle clock rin0+ rin0- rin1+ rin1- rin2+ rin2- r0 b1 na na r0 r1 g0 g1 b0 r1 rin3+ rin3- g7 u lvds option = h (3.3v) / open b2 na de de b2 b3 b4 b5 na r0 r5 g0 g0 r0 r1 r2 r3 r4 r1 g1 b0 b1 b1 g1 g2 g3 g4 g5 g2 previous cycle current cycle next cycle clock rin0+ rin0- rin1+ rin1- rin2+ rin2- r6 b7 na na r6 r7 g6 g7 b6 r7 rin3+ rin3- b3 rinclk+ rinclk- rinclk+ rinclk- pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 12/26 no reproduction and redistribution allowed backlight connector pin configuration electrical specification (lamp spec) parameter min typ max units condition ccfl current(icfl) 5.0 6.5 7.0 [ma] rms (ta=25 ) ccfl frequency(fcfl) 40 55 70 [khz] (ta=25 ) ccfl ignition voltage(vs) 1580 [volt] rms (ta= 25 ) ccfl ignition voltage(vs) 2050 [volt] rms (ta= 0 ) ccfl voltage (reference) (vcfl) 894 837 823 [volt] rms (ta=25 ) ccfl power consumption (pcfl) 32.64* 34.57 [watt] (ta=25 ) * note. pcfl = icfl x vcfl x 6 = 6.5 x 837 x 6 = 32.64 w (typ) pcfl = icfl x vcfl x 6 = 7 x 823 x 6 = 34.57 w (max) lamp connect configuration mating connector: sm02b-bhs-1-tb (jst) sm02b (pin1) connector mating way: cable color: blue/pink/white blue or white blue or white white or blue white or blue pink pink pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 13/26 no reproduction and redistribution allowed 3-3 signal timing specifications this is the signal timing required at the input of the user connector. all of the interface signal timing should be satisfied with the following specifications for it s proper operation. * timing table *1) clk signal input must be valid while power supply is applied. *2) display position is specific by the rise of de signal only. horizontal display position is specified by the falling edge of 1 st clk right after the rise of de, is displayed on the left edge of the screen. vertical display position is specified by the rise of de after a low level period equivalent to eight times of horizontal period. the 1 st data corresponding to one horizontal line after the rise of de is displayed at the top line of screen. 3.) if a period of de high is less than 1366 clk or less than 768 lines, the rest of the screen displays black. 4.) the display position does not fit to the screen if a period of de high and the effective data period do not synchronize with each other. pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 14/26 no reproduction and redistribution allowed 3-4 signal timing waveforms tclk tdisp(h) tdisp(v) tclk de de de tblk(h) tblk(v) clk clk pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 15/26 no reproduction and redistribution allowed 3-5 color input data reference the brightness of each primary color (red, green and blue) is based on the 8 bit gray scale data input for the color; the higher the binary input, the brighter the color. the table below provides a reference for color versus data input. color data reference input color data red msb lsb green msb lsb blue msb lsb color r7 r6 r5 r4 r3 r2 r1 r0 g7 g6 g5 g4 g3 g2 g1 g0 b7 b6 b5 b4 b3 b2 b1 b0 black(l0) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 red 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 green 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 blue 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 cyan 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 magenta 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 yellow 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 basic color white(l255) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 red 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 red 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ---- red 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 red red 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 green 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 green 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 ---- green 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 green green) 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 blue 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 blue 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 ------- blue 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 blue blue 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 16/26 no reproduction and redistribution allowed 3-6 power sequence values parameter min. typ. max. units t1 0.47 - 20 ms t2 20 - 50 ms t3 700 - - ms t4 10 - - ms t5 1 - 50 ms t6 - - 300 ms t7 1000 - - ms apply the lamp voltage within the lcd operating range. when the backlight turns on before the lcd operation or the lcd turns off before the backlight turns off, the display may momentarily become abnormal. caution : the above on/off sequence should be applied to avoid abnormal function in the display. in case of handling, make sure to turn off the power when you plug the cable into the input connector or pull the cable out of the connector. lvds data & clk power supply for lcd (vdd) power for lamp pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 17/26 no reproduction and redistribution allowed 4. optical specification optical characteristics are determined after the unit has been on and stable for approximately 30 minutes in a dark environment at 25 . the values specified are at an approximate distance 50cm from the lcd surface at a viewing angle of and equal to 0 . fig.4-1 optical measurement equipment and method values parameter symbol min. typ. max. units notes contrast ratio cr 600 700 1 surface luminance, white lwh 350 450 cd/ O 2 luminance variation white 9 p 1.25 3 response time t 8 16 ms 4,5 (ton+toff) rise time tr 6 12 ms decay time tf 2 4 ms color coordinates red r x 0.640 r y 0.330 green g x 0.290 g y 0.600 blue b x 0.150 b y 0.060 white w x 0.295 w y typ.-0.03 0.305 typ.+0.03 viewing angle by eldim contrast ratio>10 x axis, right( =0 ) r 65 80 degree 6, 7 x axis, left( =180 ) l 65 80 y axis, up( =90 ) u 65 70 y axis, down ( =0 ) d 55 70 pr880 or equivalent pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 18/26 no reproduction and redistribution allowed note: 1. contrast ratio (cr) is defined mathematically as: 2. surface luminance is luminance value at point 1 across the lcd surface 50cm from the surface with all pixels displaying white. from more information see fig 4-2. when i bl = 6.5ma, l wh =450cd/ O (typ.) l wh =lon1, where lon1 is the luminance with all pixels displaying white at center 1 location. fig.4-2 optical measurement point 3. the variation in surface luminance, white is defined (center of screen) as: white(9p) =maximum(l on1 , l on2 , ,l on9 )/minimum(l on1 , l on2 , l on9 ) 4. response time is the time required for the display to transition from white(l255) to black(l0) (decay time, tr d =tf ) and from black(l0) to white(l255) (rise time, tr r =tr ). the response time interval is between the 10% and 90% of 1 st frame amplitudes. for additional information see fig 4-3. fig.4-3 response time contrast ratio (cr)= brightness on the white (l255) state brightness on the black (l0) state tr d tr r 1 2 3 4 5 6 7 8 v h v/6 v/2 h/2 h/6 9 pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 19/26 no reproduction and redistribution allowed 5. viewing angle is the angle at which the contrast ratio is greater than 10. the angles are determined for the horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the lcd surface. for more information see fig 4-5. 6. to be measured with a viewing cone of 1 by topcon luminance meter eldim ez contrast 160d . fig.4-5 viewing angle definition pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 20/26 no reproduction and redistribution allowed 5. mechanical characteristics the contents provide general mechanical characteristics for the model t200xw02. in addition the figures in the next page are detailed mechanical drawing of the lcd. horizontal (typ.) 472.0mm vertical (typ.) 276.5mm outline dimension depth (typ.) 24.0mm(max.) horizontal (typ.) 448.0mm bezel area vertical (typ.) 253.8mm horizontal 443.61mm active display area vertical 249.41mm weight 3000g (max.) surface treatment hc, 3h pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 21/26 no reproduction and redistribution allowed front view: rear view: 8 6 + 0 . 2 ( r e a r m o d e ) 8 6 + 0 . 2 ( r e a r m o d e ) 155+0.2 (rear mode) 100+0.2 (rear mode) ( 3 5 ) ( 9 8 ) 91 (i/f connector) 4 7 ( i / f c o n n e c t o r ) 0.2 ? 6 ( v r h o l e ) 1 3 0 + 1 0 ( 2 x ) pin1 pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 22/26 no reproduction and redistribution allowed 6. international standard 6-1. safety (1) ul6500, underwriters laboratories, inc. (auo file number : e204356) standard for safety of information technology equipment including electrical business equipment. (2) can/csa c22.2 no. 950-95 third edition, canadian standards association, jan. 28, 1995 standard for safety of information technology equipment including electrical business equipment. (3) en60950 : 1992+a2: 1993+a2: 1993+c3: 1995+a4: 1997+a11: 1997 iec 950: 1991+a1: 1992+a2: 1993+c3: 1995+a4:1996 iec 60065 european committee for electro technical standardization (cenelec) european standard for safety of information technology equipment including electrical business equipment. 6-2. emc a) ansi c63.4 methods of measurement of radio-noise emissions from low-voltage electrical and electrical equipment in the range of 9khz to 40ghz. american national standards institute(ansi), 1992 b) c.i.s.p.r limits and methods of measurement of radio interface characteristics of information technology equipment. international special committee on radio interference. c) en 55022 limits and methods of measurement of radio interface characteristics of information technology equipment. european committee for electrotechnical standardization. (cenelec), 1998 pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 23/26 no reproduction and redistribution allowed 7. packing label sample green mark description: for pb free products, auo will add for identification. for rohs compatible products, auo will add for identification. note. the green mark will be present only when the green documents have been ready by auo internal green team. (the definition of green design follows the auo green design checklist .) carton label cushion set carton box, 320mm(w)x590mm(l)x410mm(h) carton no: customer no: made in taiwan taiwan model no: t200xw02 vx *pm100-01a1600001* qty: 6 part no: 97.20t02.xxx au o ptronics pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 24/26 no reproduction and redistribution allowed pallet package air cargo : (3 *2) *3 layers, total 18 boxes with 108 pcs panel in one pallet top view side view ocean shipping : (3 *2) *5layers, total 30 boxes with 180 pcs panel in one pellet top view side view 120 530 940 1350 1000 1180 5 9 0 320 960 1200 1760 2170 1200 120 530 940 1350 1000 1180 590 320 960 pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 25/26 no reproduction and redistribution allowed 8. precautions please pay attention to the followings when you use this tft lcd module. 8-1 mounting precautions (1) you must mount a module using holes arranged in four corners or four sides. (2) you should consider the mounting structure so that uneven force (ex. twisted stress) is not applied to module. and the case on which a module is mounted should have sufficient strength so that external force is not transmitted directly to the module. (3) please attach the surface transparent protective plate to the surface in order to protect the polarizer. transparent protective plate should have sufficient strength in order to the resist external force. (4) you should adopt radiation structure to satisfy the temperature specification. (5) acetic acid type and chlorine type materials for the cover case are not desirable because the former generates corrosive gas of attacking the polarizer at high temperature and the latter causes circuit break by electro-chemical reaction. (6) do not touch, push or rub the exposed polarizers with glass, tweezers or anything harder than hb pencil lead. and please do not rub with dust clothes with chemical treatment. do not touch the surface of polarizer for bare hand or greasy cloth. (some cosmetics are detrimental to the polarizer.) (7) when the surface becomes dusty, please wipe gently with absorbent cotton or other soft materials like chamois soaks with petroleum benzene. normal-hexane is recommended for cleaning the adhesives used to attach front/ rear polarizers. do not use acetone, toluene and alcohol because they cause chemical damage to the polarizer. (8) wipe off saliva or water drops as soon as possible. their long time contact with polarizer causes deformations and color fading. (9) do not open the case because inside circuits do not have sufficient strength. 8-2 operating precautions (1) the spike noise causes the mis-operation of circuits. it should be lower than following voltage: v= 200mv(over and under shoot voltage) (2) response time depends on the temperature. (in lower temperature, it becomes longer..) (3) brightness depends on the temperature. (in lower temperature, it becomes lower.) and in lower temperature, response time (required time that brightness is stable after turned on) becomes longer. pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net
? copyright au optronics, inc. march, 2006 all rights reserved. t200xw02 ver0.7 26/26 no reproduction and redistribution allowed (4) be careful for condensation at sudden temperature change. condensation makes damage to polarizer or electrical contacted parts. and after fading condensation, smear or spot will occur. (5) when fixed patterns are displayed for a long time, remnant image is likely to occur. (6) module has high frequency circuits. sufficient suppression to the electromagnetic interference shall be done by system manufacturers. grounding and shielding methods may be important to minimize the interface. 8-3 electrostatic discharge control since a module is composed of electronic circuits, it is not strong to electrostatic discharge. make certain that treatment persons are connected to ground through wrist band etc. and don t touch interface pin directly. 8-4 precautions for strong light exposure strong light exposure causes degradation of polarizer and color filter. 8-5 storage when storing modules as spares for a long time, the following precautions are necessary. (1) store them in a dark place. do not expose the module to sunlight or fluorescent light. keep the temperature between 5 and 35 at normal humidity. (2) the polarizer surface should not come in contact with any other object. it is recommended that they be stored in the container in which they were shipped. 8-6 handling precautions for protection film (1) the protection film is attached to the bezel with a small masking tape. when the protection film is peeled off, static electricity is generated between the film and polarizer. this should be peeled off slowly and carefully by people who are electrically grounded and with well ion-blown equipment or in such a condition, etc. (2) when the module with protection film attached is stored for a long time, sometimes there remains a very small amount of flue still on the bezel after the protection film is peeled off. (3) you can remove the glue easily. when the glue remains on the bezel or its vestige is recognized, please wipe them off with absorbent cotton waste or other soft material like chamois soaked with normal-hexane. pdf created with fineprint pdffactory pro trial version www.pdffactory.com www..net


▲Up To Search▲   

 
Price & Availability of T200XW02V0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X